Phase 0 Visualization Issues
Back to
Phase 0
Chris Bond discovered that the imaging system used to aquire the Schlierens of the flow had an
aspect ratio of 1.03 due to the different folcal lenghts involved. Also the Schlieren images
had to be post-processed to remove a 'barreling' aberration (a vertically compression of the image
that was most pronounced in the center of the image). For standarization, the final image produced
has 284 pixels per inch.
corrected image
In producing the simulation images, I discovered that Tecplot (our default viz program) uses pixels
with an aspect ratio (dx/dy) of 1.06. This is consistent with a PALS standard and has to be
corrected when comparing with the images Chris produced (which have aspect ratio 1).
After making all of these correction, our agreement is very good. As an example, this image comes
from 'Run 42', a Mach 1.507 shock, wedge angels 14.7 and 10.2 degrees with an unshocked gas pressure
of 22.75 kPa. This image was taken 0.186ms after the shock past a transducer located 13inches from
the apex of the wedge (measured in the horizontal direction)
- Run42: Using Clawpack
- WENO-TCD version
- Using a mapped mesh - done by George: