Using AMR to achieve an effective resolution of 2400x800 here are some results that compare pure WENO ( not TCD ) with clawpack (Van Leer with Muscl reconstruction) using Method(2) 4.

The first wedge angle is 15degrees and the second angle is 45degrees. The background flow is Mach 9 and gamma =1.4 One notices that the shear layer is more unstable in the WENO calculations. This persists into later times. A higher resolution clawpack (6 levels for an effective resolution of 6400x3200) confirms the features seen in the WENO simulation.

  • Colored by Density:
    Colored by Density

  • Compare with Olejniczak, Wright and Candler:
    Compare with Candler et al