2 Grid Levels (density at time t = 0.75)
Results: 2 Levels / 3 Levels
Contour lines of density on refinement grids (P=1)
| Level 0 | Level 1 |
Grids | 2 | 52 |
Cells | 67500 | 22556 |
Benchmark
Task | P=1 | P=2, GuC-Factor=2 | P=4, GuC-Factor=2 | P=2, GuC-Factor=1 | P=4, GuC-Factor=1 |
s | % | s | % | s | % | s | % | s | % |
Integration | 332 | 58.8 | 170 | 41.8 | 81 | 33.1 | 218 | 23.9 | 104 | 22.0 |
Flux correction | 41 | 7.3 | 27 | 6.6 | 15 | 6.1 | 31 | 3.4 | 19 | 4.0 |
Boundary setting | 23 | 4.1 | 97 | 23.8 | 70 | 28.6 | 93 | 10.2 | 62 | 13.2 |
Recomposition | 27 | 4.1 | 97 | 23.8 | 70 | 28.6 | 483 | 53.0 | 227 | 48.1 |
Clustering | 40 | 7.0 | 19 | 4.7 | 10 | 4.1 | 19 | 2.1 | 10 | 2.2 |
Misc. | 102 | 18.0 | 44 | 10.8 | 30 | 12.2 | 58 | 7.4 | 40 | 10.5 |
Total / Parallel Efficiency | 565 | 100.0 | 407 | 69.4 | 245 | 57.7 | 901 | 31.4 | 462 | 30.6 |
If a relatively fine base grid is used, the choice of a larger GuC-Factor can decrease the overhead for partitioning and recomposition significantly. In this example, the partitioner can use up to 67500 units for GuC-Factor=1, while for GuC-Factor=2 only up to 16875 units are allowed.
<--- Problem description
--
RalfDeiterding - 04 Dec 2004